Boiler Truma Electric incl. waster set ABO

Boiler Truma Electric incl. waster set ABO

The electric boiler with a capacity of 14 litres heats the water via an electric heating element. The water is heated from approx. 15 to 70°C in approx. 70 minutes. The innovative EPP housing insulates the boiler against heat loss. Thanks to this special insulation, the water temperature only drops by 1°C per hour.

  • Fast heating-up time thanks to the electric heating element
  • Power consumption at 230 V: 3.7 A
  • Low standstill losses of only 1.1 K/h thanks to EPP foam insulation – that means it can only be switched on again after approx. 9 hours after heating up
  • Maximum pump pressure up to 2.8 bar – this means that all common pressure or submersible pumps can be used
  • Temperature limitation at 70°C
  • Overtemperature protection at 90°C
  • 14 litre stainless steel container – corrosion resistant and suitable for drinking water
  • Easy installation – also retrofitted into existing water systems
  • Standard connection for flexible water hoses with an inner diameter of 10 mm or for fixed water pipe laying (e.g. John Guest System)
  • Extensive accessories

Contents:
operating unit
3 m cable
Drain and vent valve (ABO)

 

  • Weight: 3 kg
  • Width: 40,5 cm
  • Height: 29,5 cm
  • Length: 40,5 cm
  • Power: 850 W
  • Volume: 14 l
  • Max. pump pressure: 2,8 bar
  • Properties: corrosion-resistant
  • Max. temperature: 70 °
  • Functions: Short heat-up times
  • Voltage: 230 V
  • Current strength at 230 V: 3,7 A
  • Kirjeldus

      The electric boiler with a capacity of 14 litres heats the water via an electric heating element. The water is heated from approx. 15 to 70°C in approx. 70 minutes. The innovative EPP housing insulates the boiler against heat loss. Thanks to this special insulation, the water temperature only drops by 1°C per hour.

      • Fast heating-up time thanks to the electric heating element
      • Power consumption at 230 V: 3.7 A
      • Low standstill losses of only 1.1 K/h thanks to EPP foam insulation – that means it can only be switched on again after approx. 9 hours after heating up
      • Maximum pump pressure up to 2.8 bar – this means that all common pressure or submersible pumps can be used
      • Temperature limitation at 70°C
      • Overtemperature protection at 90°C
      • 14 litre stainless steel container – corrosion resistant and suitable for drinking water
      • Easy installation – also retrofitted into existing water systems
      • Standard connection for flexible water hoses with an inner diameter of 10 mm or for fixed water pipe laying (e.g. John Guest System)
      • Extensive accessories

      Contents:
      operating unit
      3 m cable
      Drain and vent valve (ABO)